Router HA: keep internet and LAN up while one RB5009 reboots #46
Labels
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set
Reference
lab/iac#46
Loading…
Reference in a new issue
No description provided.
Delete branch "%!s()"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Part of lab/iac#43.
Goal: reboot either RB5009 (RouterOS upgrades) without losing internet. Research and decide:
Done when
Decided layout (2026-11-05):
Checks before this is final:
Research, 2026-11-05:
Bell and concurrent PPPoE. A Bell forum answer marked as the solution says: "Bell doesn't have a limit on the number of concurrent PPPoE sessions. We are okay with multiple PPPoE sessions, as long as it's not on different DSL/FTTH ports concurrently" (forum.bell.ca thread 25633). Users report up to 4 simultaneous sessions, each with its own dynamic public IP. Static-IP business plans hand every session the same IP. So two sessions, one per router, over the same fiber port are allowed.
Caveat: a Jan 2026 Bell forum thread (Giga Hub 2.0, 3 Gbps plan) reports that a downstream PPPoE session through pass-through stays capped around 1/1 Gbps while the hub's own NAT gets more. Measure each router's session separately.
RB5009 over PPPoE. MikroTik forum reports vary:
PPPoE leans on one CPU core per session, so two sessions (one per router) also spread the load. The current 1.5 Gbps plan is borderline-to-fine. An 8 Gbps plan is out of reach for an RB5009.
Current state. The ER-X-SFP's ports, SFP included, are all 1G, so today's WAN is already capped at about 940 Mbps whatever the plan says. A speed test will confirm it.
Done. Decision recorded in accepted ADR-0008 (.1 VRRP gateway, .2/.3 routers, per-router PPPoE so WAN needs no shared segment; MLAG not used, dual-homed hosts ride through via bonds on mini and the workstation). Rehearsed and measured twice: scripted reboots (failover 3.3s / backup reboot 0 loss, iac notes 2026-11-16) and manual cable-pull of both routers 2026-11-17 (zero observable loss from workstation vantage, 1007 samples). Residual gap tracked separately as #128 (failback ordering); 8Gbps-class throughput question deferred to a future WAN change.